Application
© The actual status of overhead power lines
Operating Temperature
© -40°C~+70°C
Water-blocking construction Moisture-proof and prevents water penetration
Special filling gel in loose tubes Reduce or eliminate reflection losses and prevent water penetration Eliminates
All dielectric construction design electromagnetic induction effect
Strict craft and raw material control enable Lifespan over 30 years
Customized longitudinal color strip Easy identification, packing and maintenance
Note:
©According to different applications, anti-termite and anti-rodent are optional.
© For flame retardant cable, LSZH (Low-Smoke Zero Halogen) material is applicable to outer sheath and the type is GYFZCY
◎ Longitudinal color strip on outer sheath can be provided according to customer's requests. More details, please refer to GYFZA.
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Max Fibers per Tube | No. of (Tubes + Fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/lOOmm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~36 | 10.7 | 92 | 6 | 6 | 2700 | 1000 | 1000 | 300 |
38-72 | 11.6 | 103 | 12 | 6 | 2700 | 1000 | 1000 | 300 |
74-96 | 13.3 | 149 | 12 | 8 | 2700 | 1000 | 1000 | 300 |
98-120 | 14.8 | 180 | 12 | 10 | 2700 | 1000 | 1000 | 300 |
122-144 | 16.4 | 222 | 12 | 12 | 2700 | 1000 | 1000 | 300 |
146-216 | 18.8 | 224 | 12 | 18 (2layers) | 2700 | 1000 | 1000 | 300 |
>216 | Available upon customer's request |
•Customized cable structure is available